Core Principle: Electrochemical Activation
Envirolyte systems operate on electrolysis of a dilute salt solution (brine).
NaCl + H2O + electricity -> oxidizing and alkaline solutions
The process occurs inside a specially designed electrochemical reactor
Key System Components
Envirolyte systems operate on electrolysis of a dilute salt solution (brine).
Electrolytic Cell – Anode, Cathode, and Diaphragm
Electrochemical Reactions
Redox reaction – Electrons are transferred between atoms
At the Anode – Chloride Ions are oxidized (losing electrons), chlorine reacts with water, Hypochlorous Acid (HOCl) is formed
At the Cathode – Water is reduced (gaining electrons), alkaline solution is formed, hydrogen gas is vented safely
Solution Types Produced
Oxidizing Solution (Anolyte) – Strong disinfectant, High oxidation-reduction potential, Neutral or slightly acidic pH
Alkaline Solution (Catholyte) – High pH, Good degreasing / cleaning ability
Control Parameters
Current Density – Determines rate of chlorine species production
Flow Rate – Controls contact time in reactor and concentration of output solution
Salt Concentration – Affects conductivity, efficiency, and production composition
pH Control – Determines the dominant species in HOCl, (5-6) Most Effective; (>8) Least Effective